Key Features
1.Height is printed on the matrix to ease identification
2.All matrices are 75 microns thick & anatomically preshaped.
3.Evolve matrices come in three shapes and multiple heights.
4.Matrices' translucence allows for three point curing of composite.
5.Stiffer than other mylar & easy to place.
Color :
Blue
Orange
Pink
Size :

BioClear Evolve Matrices - Anatomically Pre-shaped Posterior matrices are in three widths

Evolve matrices are an evolution in posterior matrices - an improvement on what was already the most advanced and user-friendly mylar matrix in modern posterior restorations, the BioClear Biofit HD, the Evolve Matrices have the same benefits and additional features for posterior cases.

The new features of the BioClear Evolve Matrix Series include:

  • Three emergence profile shapes that are color-coded on the
  • Matrix heights printed on the matrix for quick identification
  • Extra-flared quick-release tabs on the buccal and lingual surfaces that are easier to find and use
  • Wide array of sizes (heights) available (the blue comes in 5, 6, 7, 8, and 9mm’s, the orange comes in 6, 7, and 9mm’s, and the pink comes in 6, 7, and 9mm’s)

Blue Evolve:

The Blue Evolve Matrix is color-coded to be easily seen, features an aggressively rounded emergence profile, and comes in five heights to provide an ideal fit.
The occlusal curvature of the matrix creates a rounded marginal ridge with ease. The size and shape is appropriate for most posterior molar cases.
The Blue Evolve's shape is the most curvaceous of all of our posterior matrices and requires a unique insertion method.
To place the matrix, rotate it into place from top to bottom. Doing this expands the base of the matrix so it snaps over the tooth and into place.

Orange Evolve:

This matrix features a flatter emergence profile curvature than the Blue Evolve but is not as flat as the Pink Evolve matrix. The Orange Evolve Matrix is color-coded to be easily seen, features a flatter emergence profile curvature, and comes in three heights to provide an ideal fit.
Orange Evolve was created for instances where the Blue Evolve Matrix or Biofit HD Matrix would invert.

This commonly occurs between maxillary 1st and 2nd molars.

Used For:
•Teeth with root proximity
•Flat teeth

The root proximity often causes a normal sectional matrix to invert occluso-gingivally and buccal-lingualy.
Orange Evolve’s shape is a middle ground between the blue, which is very curvaceous, and pink, which is our flattest posterior matrix.

Pink Evolve:

Commonly used between maxillary 1st and 2nd molars in cases of broad teeth, tight root proximity, or very flat teeth. Often referred to as the Broad Flat Molar Matrix. The Pink Evolve Matrix is color-coded to be easily seen, features a broad emergence profile curvature, and comes in three heights to provide an ideal fit.

Pink Evolve was created for instances where the Blue Evolve Matrix, Biofit HD Matrix, or Orange Evolve Matrix would invert. This commonly occurs between maxillary 1st and 2nd molars.

Used For:
•Very Broad teeth
•Teeth with extreme root proximity
•Very flat teeth


The interproximal of the 1st and 2nd maxillary molars is often much wider buccal-lingually than any other embrasure areas. This can cause a traditional sectional matrix to invert buccal-lingually. The root proximity often causes a normal sectional matrix to invert occluso-gingivally and buccal-lingualy.

Pink Evolve’s shape is our flattest posterior matrix.


The Bioclear Evolve Matrix Height Indicator

The Bioclear Evolve Matrix Height Indicator is used for posterior restorations and has two uses:

Matrix Height Indicator: Numbers are printed on the indicator so the correct Evolve matrix for a restoration is chosen the first time. This helps reduce waste when incorrect matrices are chosen.

Go/No-Go Indicator: The colored tip indicates if a cavity prep can be cured in one layer or if more must be used.


For posterior class II restorations
For MOD restorations
Tansluscent mylar-75micron thick
Blue matrices sizes-5,6,7,8,9[ mm ]
Orange matrices sizes-6,7,8 [mm ]
Pink matrices sizes-6,7,8 [ mm ]
1.MATRIX SELECTION
There are three lines of Bioclear Evolve Matrices: Blue, Orange and Pink. Matrix selection is primarily based on doctor preference but, in general, Blue Evolve is suitable for most all posterior cases. Orange Evolve features a flatter, less rounded, emergence profile and is slightly wider than Blue. Pink Evolve is the broadest of the three and has a flat emergence profile that is easier to use on broad, very flat teeth, or teeth with tight root proximity.
2.TWIN RING TIPS
The Bioclear Forceps are specifically designed for safely and securely opening and placing the Twin Ring. Ensure that the tines of the forceps are completely engaged with the plastic handles of the Twin Ring (see illustration). If they are not fully engaged or if the tines are seated on the metal, they can cause the Twin Ring to break. There are two types of Twin Rings: purple, for molars, and yellow, for pre-molars. DO NOT use alcohol wipes or other cold sterilization methods—this will void the warranty.
3.THE BIOCLEAR PUSH-PULL INSTRUMENT
The Bioclear Push-Pull Instrument was created to ensure tight contacts, particularly when there is not interproximal tooth structure to hold the matrix tightly to the adjacent tooth.
4.DEEP MARGIN ACQUISITION (DMA)
Pre-wedging creates good margin access, but some cases require deeper access. DMA is a combination of technique and cutting-edge product that allows the creation of a much deeper, high-quality margin than has previously been possible.

DMA PROTOCOL

Technique:
Pack a #3 cord moistened with astringent in the interproximal aggressively to temporarily release the periodontal ligament. Remove the cord, and then blast. In summary, the cord is packed aggressively, and then removed immediately. No cord is present when the matrix is "placed".

Product:
The taller, extensioned Bioclear Evolve Matrices (7, 8, & 9) facilitate the DMA. The DMA protocol allows the extension of the matrix to seat deeply enough to use the periodontal ligament as a seal, eliminating problems such as overhangs. Anytime you desire that the matrix seat deeper, the DMA protocol can be utilized regardless of matrix height; however the best results will be obtained by using a taller matrix with an extension.
CLINICAL TIPS-
Use a rubber dam. Choose the correct matrix. Use Bioclear Evolve Matrices for three point curing—their translucence is key to curing bulk-fills. Use Bioclear Forceps—designed specifically for the Twin Ring. Ensure proper matrix orientation—the tab should opposite of the gingival. Seat the matrix deep into the sulcus. Always pre-wedge to facilitate a great outcome.

Storage
Store at cool and dry place

Customer Reviews

No reviews yet
0%
(0)
0%
(0)
0%
(0)
0%
(0)
0%
(0)
You have successfully subscribed!
This email has been registered
ico-collapse
0
Recently Viewed
Top
ic-expand
ic-cross-line-top