Sale
Sold Out
Zoom the image with mouse

Bioclear TruContact saw - Designed to use with Bioclear Matrix system

Bioclear
1 x TruContact Red
1 x TruContact Orange
1 x TruContact Blue
Rs. 5,315 Rs. 7,875
Bioclear TruContact Saws and Sanders designed to work in sequence with Bioclear Matrices
1.Lighten the contact
2.Improves the ease of placement of matrices.
3.Available in different sizes/sanders
4.Color coded

Subcribe to back in stock notification

TruContact Saws and Sanders-For contact optimization along with Bioclear matrix system

Contact optimization is an essential part of the Bioclear Method. Natural contacts are generally too tight and too rough to allow insertion of a mylar matrix.

Bioclear TruContact Saws and Sanders are designed to work in sequence to lighten the contact which then improves the ease of placement of the mylar matrices. As an additional advantage, the TruContact also removes biofilm from the contact

  • Use the Orange ultra-thin single-sided saw to cut into tight interproximal spaces and adjust the proximal contact with the combination of an abrasive diamond surface and a saw tooth edge
  • Use the Blue heavy single-sided saw for more rigorous cutting and cleaning
  • Reduce interproximal enamel on two adjacent teeth with the Red double-sided, medium, diamond, serrated strip
  • Autoclavable up to 280 times (steam heat only, not dry heat)

 

Use TruContact with the Black Triangle Matrices

Bioclear is pleased to introduce the Black Triangle System, a new matrix system that enables black triangle closure up to 40% faster* than with the original Bioclear matrices.

Black Triangle matrices are custom designed for black triangle treatment and require no trimming prior to seating.

A color-coded gauge and matrices make choosing the correct curvature for gingival embrasure closure simple and predictable. Curvature is indicated by colors at the top of the matrix and correspond with a gauge that, when inserted into the black triangle, indicates which curvature to use.

The matrices come in two sizes (large incisor and small incisor) and four curvatures allowing you to treat the entire anterior sextant, canine to canine and both upper and lower arches with strong aesthetically pleasing results.

Black triangle Matrices

Using paired matrices, curvature (indicated by color) closes spaces up to:

Pink – 1 mm space
Yellow – 1.5 mm space

Green – 2 mm space
Blue – 2.5 mm space

1. Small Incisor BT Matrix Tub: For mandibular incisors and small maxillary lateral incisors

2. Large Incisor BT Matrix Tub: Are taller and wrap the tooth more than the Small Incisor BT Matrices. They should be used for maxillary central Incisors, large maxillary lateral incisors, maxillary and mandibular canines, and maxillary and mandibular bicuspids.

Black Triangle Gauge

The BT Gauge is for use with the new color-coded BT Matrices. The use of the gauge with these color-coded matrices is designed to make black triangle closures simpler and more efficient.

 


Dual Color Disclosing Solution

Disclosing solution for discovery of cracks and biofilm for blasting. Newer Biofilm stains pink. Older biofilm & cracks (more than 24 hours) stain purple, aiding the clinician in properly educating patients about oral hygiene & restorative needs.

 

Cleaning & Sterilization

1. BT Gauges and TrueContact Saws and Sanders are reusable and autoclavable. Wash with soap and water using a soft brush to remove debris
Note: Do NOT use sprays/wipes, this could damage the BT Gauge.
2. Sterilize using steam sterilizers only on the regular cycle
Note: Temperature of sterilizer should NOT exceed 270° F/132° C

1 For contact optimization before placing the matrix.
2 Improves the ease of placement of the mylar matrices
ORANGE Saw-Light single sided Sander
BLUE Saw-Heavy single sided sander
Red Saw- Heavy Double sided
1.TRUE CONTACT
Use the TruConact sander before matrix placement to lighten the contact between teeth where the matrix is to be placed.
• If you are placing the matrix on one tooth surface, use the orange sander.
• If you are placing two matrices in one contact, use the red sander.
• Use the blue saw after curing the composite to clean up any unwanted materials in the interproximal area to avoid “false contact.”

2.Finished Cavity Preparation
For most cavities, no mechanical retention via box shape is needed when the proper Clark Class II preparation is cut.
2.Run Sanding Strip Through Contact
The contact area must be lightly broken. This step is much safer using a 3M equivalent lightening strip, not a bur, to protect the neighboring tooth.
3.Place Biofit Matrix and Largest Wedge
The Biofit HD matrix is rugged and will withstand heavy seating pressure. Trap the “tab” against the neighboring marginal ridge during insertion to keep matrix fully seated and stable.

Storage
Store at cool and Dry place

Customer Reviews

No reviews yet
0%
(0)
0%
(0)
0%
(0)
0%
(0)
0%
(0)
Bioclear TruContact saw - Designed to use with Bioclear Matrix system
You have successfully subscribed!
This email has been registered
ico-collapse
0
Recently Viewed
Top
ic-expand
ic-cross-line-top